HVC806A0 X-Ray Source

Key Features:
●Integrated design with high electrical integration and a compact appearance
●Capable of continuous, long-term operation
●High stability
●Versatile installation options
●Standard digital interface for easy use
  • Detail
  • Parameters

Product Details

The HVC806A0 is a compact, safe, and electrically stable integrated X-ray source with low leakage. It operates continuously at 240W within the allowable temperature range. The system includes a high-voltage power supply, filament power supply, X-ray tube, high-voltage oil tank, and radiator. This high-frequency, self-cooling, and self-protecting X-ray generator delivers up to a maximum voltage of up to 80kV and a maximum power of 240W. It mainly consists of a control box and high-voltage oil tank, with RS232 communication for control, monitoring, and firmware upgrades.

Application:

Food testing, industrial non-destructive testing, dangerous goods testing and other fields, mostly used for simple X-ray machines or mobile X-ray testing equipment

Specification:

Item

Specification

Input voltage

230VAC±10%, 50/60Hz, 3Amps

Output power of X ray tube

Max continuous output power 240W80kV/3mA,40kv/6mA

Output voltage

Rated output voltageContinuously adjustable voltage range 30kV—80kV

Output voltage ripple±0.5%peak to peak

Output voltage accuracy±2% of voltage setting value

line regulation±0.1%

load regulation±0.1%

Tube current

Rated tube currentContinuously adjustable current range 1mA-6mA

Tube current accuracy±0.2mA of current setting value

line regulation±0.1%

load regulation±0.1%

Rise time of output voltage

The kV rise time is <0.6 Sec at maximum power

The kV rise time is <0.1 Sec at low voltage ( < 40kV )

Filament power supply:

input voltage24VDC

filament voltage2.0 to 5.3V

filament3.0 to 3.8Amps RMS

preheating time3sec

Tube feature

Tube typefixed anodeglass envelopetungsten target

focus0.8mm

inherent filtration0.8mm Be1.5mm AI

radiation angle80º*16ºfan beam

target angle25°

Cooling

transformer oilexternal circulationexternal forced air cooling

Working temperatures

-10℃—40℃

Storing temperature

-20℃—60℃

System temperature protection

60℃±3℃ of oil temperature

Humidness

98%Non- condensation

Weight

31.1kg

Installation direction

Installation in any direction

Radiation angle

16°×80°

X-ray leakage

Less than 0.5mR/hr at 5cm from the surface of the HVC806A0.

JB1/AC~(AC Input Power Connector)

Pin

Signal

Parameter

1

L

live wire

2

N

Neutral line

3

G

PE

1.jpg

JB2/COM (DMR-9S interface definitions)

Pin

Signal

Parameter

1.4.6.7.8.9

N/C

No connect

2

TXD

Data transmit

3

RXD

Data receive

5

GND

Signal gnd

2.png

JB3/Interlock,(DMR-9P interface definitions)

Pin

Signal

Parameter

3/4/5/6/7/8/9

N/C

No connect

1

Interlock Out


2

Interlock In


3.png

Short connect pin1 and pin2 make X ray source normal operation. Typical connection

4.png

Led indicator:

ID

Color

Meaning

XrayOn

Yellow

indicate X ray on

ARC

Red

Arcing in oil tank

OT

Red

Over temperature

EP_Err

Red

Tube voltage error

IP_Err

Red

Tube current error

Power

Green

Power on

Tank size